3300 (1) 3PAR (1) Active Directory (1) ADFS (1) Admin Share (1) Auto-Sync (2) Auto-Sync locked (1) AWS (3) AzCopy (1) Azure (3) Backups (2) Broadcom (1) Call Forwarding (1) CLI (2) cmd (1) Compatibility View (1) Dameware MRC (1) Databases (1) DFS (1) DNS (1) Domain Admin (1) domain controller (1) Enterprise Mode (1) ESXi 5.0 (1) ESXi 5.1 (5) ESXi 5.5 (3) Exchange (3) Exchange 2010 (5) Extreme (1) ExtremeXOS (1) Federation (1) File Share (1) FSMO (1) GPO (1) Group Policy (1) Group Policy Client (1) Hardware Acceleration (1) Helpdesk (1) HP-UX (1) Hyper-V (2) IAM (1) IE10 (1) IE11 (1) IP conflict (1) Kayako (3) LDAP (1) Licence (1) Links (9) local groups (1) LUN lock (1) LUN number (1) MAC address (1) Microsoft Teams (1) Mitel (1) Namespaces (1) Networking (6) Nexenta (6) NMC (1) Office 365 (4) OneDrive (1) Outlook 2003 (1) Outlook 2013 (1) PC (1) Physical (1) PowerCLI (10) Powershell (10) promoted links (2) Public Folders (1) RDP (1) RDS (1) Recovery Services (1) RedShift (1) Registry (3) Reports (1) Resolve (2) Restart (1) RSA (1) Run As (1) SAML (1) SAN (1) Scavenging (1) script (10) Server 2003 (3) Server 2008 R2 (1) Server 2012 R2 (2) Servers (2) sharepoint 2013 (3) SMTP (3) Snapshot (2) SRM (1) SSH (5) SSL Certificate (2) Temporary profile (1) Terminal Server (3) Troubleshooting (5) Ubuntu (1) Update Manager (1) Useful Apps (1) VAAI (1) vCenter Server Appliance (1) VDI (1) VDP (1) Veeam Backup and Replication (2) VM (1) VM Error (1) vmdk (1) VMFS (1) vMotion (2) VMware (20) VoiP (1) vSphere 5.5 (4) vSphere 6.0 (2) vSphere 6.5 (1) vUM (1) webpart (1) Windows (3) Windows 10 (1) Windows 7 (2)

Friday, 12 July 2013

Veeam B&R - Hot Add Is Not Supported For This Disk

When backing up a VM using Veeam Backup and Replication, I kept seeing the message;
Hot add is not supported for this disk, failing over to network mode...
This was occurring because the LUN that my Veeam proxy server was running on was formatted in VMFS-3, whilst the server I was trying to back up was on a LUN running VMFS-5 and had a different block size.

After upgrading the proxy LUN to VMFS-5, disks began hot-adding successfully.

No comments:

Post a Comment